TROUBLESHOOTING & REPAIR

F-22

F-22

IDEALARC CV-400

STATIC SCR/DIODE RECTIFIER BRIDGE TEST (continued)

FIGURE F.9 – CONTROL BOARD AND SNUBBER BOARD PLUG LOCATIONS

FIGURE F.10 – CAPACITOR STRAP LEAD CONNECTIONS

SMALL LEAD
TERMINAL

POSITIVE
CAPACITOR
STRAP LEAD

TEST PROCEDURE

1. Disconnect the main input supply power to

the machine.

2. With the 5/16” nut driver, remove the case

top and sides.

3. Disconnect the welding cables from the

welding output terminals.

4. Locate and remove molex plug P3 from the

control board. See Figure F.9.

5. Locate and remove molex plug P5 from the

snubber board. See Figure F.9.

6. Locate and remove lead #204 from resistor

R2 (7.5 ohms, 100 watts). See Figure F.14.

7. Using the 9/16” wrench, remove the positive

capacitor strap lead and small lead terminal
from the rectifier plate and output shunt junc-
tion. See Figure F.10.