WELDING CAPABILITY

The CV-400 has the following duty cycle ratings. If the
duty cycle is exceeded, a thermal protector will shut off
the machine output until it cools to normal operating
temperature. The amber thermal protection indicator
light will turn on until the machine cools.

*Based on a 10 minute time period. For example, a 60% duty cycle
means 6 minutes on and 4 minutes off.

LIMITATIONS

The IDEALARC CV-400 has no provisions for parallel-
ing. It should not be used outdoors without rain shel-
tering.

OPERATION

B-4

B-4

IDEALARC CV-400

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Duty Cycle*

Amps

Volts

100%

400

36

60%

450

38

50%

500

40