5. Extend wire feeder control cable lead #21 so it can

be connected directly to the work piece.

a. Make a bolted connection using AWG #14 or larg-

er insulated wire. Tape the bolted connection with
insulating tape.

b. An S-16586- X remote voltage sensing work lead

is available for this purpose.

c. Keep the #21 lead electrically separate from the

work cable circuit and connection.

d. Tape the #21 lead to the work cable for ease of

use.

NOTE: The connection diagram shown in

Figure C.2

shows the electrode connected for positive polarity. To
change polarity:

a. Set the CV-400 POWER toggle switch to the OFF

(0) position.

b. Move the electrode cable to the negative (-) output

terminal.

c. Move the work cable to the positive (+) output ter-

minal.

d. Set the VOLTMETER toggle switch to negative.

CONNECTING THE NA-5 TO THE
IDEALARC CV-400

1. Set the CV-400 POWER toggle switch to the OFF (0)

position.

2. Disconnect main AC input power to the CV-400.

3. Connect the wire feeder control cable leads to the

CV-400 terminal strip as shown in Figure C.3.

4. Connect the wire feeder control cable ground lead to

the frame terminal marked .

NOTE: The CV-400 must be properly grounded.

ACCESSORIES

C-4

C-4

IDEALARC CV-400

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

FIGURE C.3

NA-5 WIRE FEEDER CONNECTION TO THE CV-400

+

-

ELECTRODE
CABLE TO
AUTOMATIC
EQUIPMENT

TO
WORK

NEGATIVE

POSITIVE

TO

AUTOMATIC

CONTROL

BOX

NA-5 WIRE
FEEDER
CONTROL
CABLE

21

4

2

BLANK

31

32

75

76

77

GND

77

76

75

32

31

2

4

21

TERMINAL

STRIPS

Advertising