LSI 7202CP User Manual

Page 27

Advertising
background image

BIOS Features

3-9

Copyright © 2001, 2002 by LSI Logic Corporation. All rights reserved.

ok

/pci@8,700000/IntraServer,fc@1

identifies the first Fibre Channel interface on an LSI Logic LSIFC929-
based adapter

/pci@8,700000/IntraServer,fc@1,1

identifies the second Fibre Channel interface on an LSI Logic
LSIFC929-based adapter

An LSI Logic LSIFC909-based adapter shows only one such Fibre
Channel device

Note:

The above are examples. The output of

show-devs

may

vary depending on your system and configuration. Use the
corresponding entries on your system, not the ones given
here.

If these devices are not listed, check that the adapter is correctly
installed, and re-seat the adapter if necessary.

3.1.5.4 Adapter-Specific Settings

In certain circumstances, the advanced user may want to change
settings for an individual adapter or port, without affecting the other
adapters in the system. Specific examples of such settings are Fibre
Channel bus speed, host adapter ID (SCSI only: Not Applicable to Fibre
Channel), and Interrupt Coalescing.

To select a specific Fusion-MPT adapter as the current adapter, use the

select

command. Selecting a port or adapter will bring the port online,

and will allow you to show or set certain adapter specific parameters.

You should use caution while issuing the following commands, as certain
commands could render the bus unusable (such as forcing 1 Gbit/s
operation on a 2 Gbit/s Fibre Channel loop).

select – Use the

select

openboot command to select the adapter entry.

This will open the port to bring the port online.

ok select /pci@8,700000/IntraServer,fc@1

.properties – Use .

properties

to show the adapter properties.

ok .properties

Advertising