Lenovo 6528 User Manual

Page 175

Advertising
background image

v

Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.

v

See the

Parts Listingsection in the Hardware Maintenance Manual to determine which components are

customer replaceable units (CRU) and which components are field replaceable units (FRU).

v

If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.

A Uncorrectable Bus Error has
occurred on system %1.
(%1 = CIM_ComputerSystem.
ElementName)

Error

A bus uncorrectable error
has occurred.
(Sensor = Critical Int CPU)

1. Check the system-event log.

2. Check the microprocessor

error LEDs.

3. Remove the failing

microprocessor from the
system board.

4. Check for a server firmware

update.
Important: Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify
that the latest level of code is
supported for the cluster
solution before you update
the code.

5. Make sure that the two

microprocessors are
matching.

6. (Trained service technician

only) Replace the system
board.

A Uncorrectable Bus Error has
occurred on system %1.
(%1 = CIM_ComputerSystem.
ElementName)

Error

A bus uncorrectable error
has occurred.
(Sensor = Critical Int DIM)

1. Check the system-event log.

2. Check the DIMM error LEDs.

3. Remove the failing DIMM

from the system board.

4. Check for a server firmware

update.
Important: Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify
that the latest level of code is
supported for the cluster
solution before you update
the code.

5. Make sure that the installed

DIMMs are supported and
configured correctly.

6. (Trained service technician

only) Replace the system
board.

Chapter 8. Troubleshooting

159

Advertising
This manual is related to the following products: