Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.

v

See the

Parts Listingsection in the Hardware Maintenance Manual to determine which components are

customer replaceable units (CRU) and which components are field replaceable units (FRU).

v

If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.

Redundancy Cooling Zone 1 has
been reduced.

Error

Redundancy has been lost
and is insufficient to continue
operation.

1. Make sure that the connector

on fan 1 and fan 4 (if
installed) is not damaged.

2. Make sure that the fan

connectors on the system
board are not damaged.

3. Make sure that the fan cage

is correctly installed.

4. Reseat the fan.

5. Replace the fan.

Redundancy Cooling Zone 2 has
been reduced.

Error

Redundancy has been lost
and is insufficient to continue
operation.

1. Make sure that the connector

on fan 2 and fan 5 (if
installed) is not damaged.

2. Make sure that the fan

connectors on the system
board are not damaged.

3. Make sure that the fan cage

is correctly installed.

4. Reseat the fan.

5. Replace the fan.

Redundancy Cooling Zone 3 has
been reduced.

Error

Redundancy has been lost
and is insufficient to continue
operation.

1. Make sure that the connector

on fan 3 and fan 6 (if
installed) is not damaged.

2. Make sure that the fan

connectors on the system
board are not damaged.

3. Make sure that the fan cage

is correctly installed.

4. Reseat the fan.

5. Replace the fan.

Sensor RAID Error has transitioned
to critical from a less severe state.

Error

A sensor has changed to
Critical state from a less
severe state.

1. Check the hard disk drive

LEDs.

2. Reseat the hard disk drive for

which the status LED is lit.

3. Replace the defective hard

disk drive.

The Drive n Status has been
removed from unit Drive 0 Status.
(n = hard disk drive number)

Error

A drive has been removed.

Reseat hard disk drive n.
(n = hard disk drive number)

164