v

Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.

v

See the

Parts Listingsection in the Hardware Maintenance Manual to determine which components are

customer replaceable units (CRU) and which components are field replaceable units (FRU).

v

If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.

Memory DIMM Configuration Error
for All DIMMs on Memory Subsystem
All DIMMs.

Error

A DIMM configuration error
has occurred.

Make sure that DIMMs are
installed in the correct sequence
and have the same size, type,
speed, and technology.

Memory uncorrectable error detected
for DIMM One of the DIMMs on
Memory Subsystem One of the
DIMMs.

Error

A memory uncorrectable
error has occurred.

1. If the server failed the POST

memory test, reseat the
DIMMs.

2. Replace any DIMM that is

indicated by a lit error LED.
Note: You do not have to
replace DIMMs by pairs.

3. Run the Setup utility to enable

all the DIMMs.

4. Run the DSA memory test.

Memory Logging Limit Reached for
DIMM One of the DIMMs on Memory
Subsystem One of the DIMMs.

Error

The memory logging limit
has been reached.

1. Update the server firmware to

the latest level.
Important: Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify
that the latest level of code is
supported for the cluster
solution before you update
the code.

2. Reseat the DIMMs and run

the DSA memory test.

3. Replace any DIMM that is

indicated by a lit error LED.

Memory DIMM Configuration Error
for One of the DIMMs on Memory
Subsystem One of the DIMMs.

Error

A DIMM configuration error
has occurred.

Make sure that DIMMs are
installed in the correct sequence
and have the same size, type,
speed, and technology.

Memory uncorrectable error detected
for DIMM n Status on Memory
Subsystem DIMM n Status.
(n = DIMM number)

Error

A memory uncorrectable
error has occurred.

1. If the server failed the POST

memory test, reseat the
DIMMs.

2. Replace any DIMM that is

indicated by a lit error LED.
Note: You do not have to
replace DIMMs by pairs.

3. Run the Setup utility to enable

all the DIMMs.

4. Run the DSA memory test.

5. (Trained service technician

only) Replace the system
board.

166