System connections, Basic system, Connection with video multiplexer – Panasonic WJ-DR200 User Manual

Page 10: Wj-dr200 system setup, Wj-dr200 setup menu video input -8, Shown below is a typical connection scenario, For continued protection, Afin d' assurer une, Ser. no

Advertising
background image

WJ-DR200 Setup Menu

VIDEO INPUT

-8-

SYSTEM CONNECTIONS

Basic System

Shown below is a typical connection scenario.

CAUTION

- FOR CONTINUED PROTECTION

Manufactured by Matushita Communication
I n d u s t r i a l C o . L t d Y o k o h a m a J a p a n

- AFIN D' ASSURER UNE

ATTENTION

AGAINST FIRE HAZARD REPLACE ONLY WITH
SAME TYPE FUSE

PROTECTION PERMANENTE CONTRE LES RISQUES
D' INCENDIE REPLACER UNIQUEMENT PAR UN
FUSIBLE DE MEME TYPE

POWER 120V AC 60 Hz 38W

VIDEO OUT 1V [ p-p ] 75

FOR COMMERCIAL USE ONLY

Made In Japan

SIGNAL GND

120V AC 60Hz

OFF

125V 4 A

POWER
ON

GND

SENSOR IN

ALARM IN

ALARM RESET IN

SERIES REC IN

TIME ADJUST IN

GND

ALARM OUT

ALARM RECOVER OUT

ALARM REC

REC

DISC

BUZZER OUT

SYSTEM ERROR OUT

THERMAL ERROR OUT

TIME ADJUST OUT

SERIES REC OUT

LED

MONITOR

CAMERA SW OUT

AUDIO

PARALELL CONTROL

SERIAL CONTROL

IN

OUT

S-VIDEO

OUT

S-VIDEO

VIDEO OUT

VIDEO IN

B

A

SER.

NO.

6 Z A 0 0 0 0 1

OUTPUT LEVEL

H
L

Camera

Video Monitor

(Alarm)

(Sensor)

(VIDEO OUT)

(VIDEO IN)

WJ-DR200

Requirements for alarm and sensor input are as follows:

• Open collector output or no-voltage make contact
• The voltage between Ground and Alarm Input or Sensor Input when the circuit closes must be 0 to 0.2 V. The polarities

can be changed by setting the SIGNAL TYPE parameter in the Alarm Recording menu.

Notes:

• Recording of freeze pictures from VCR playback is not provided as a function. Recording is possible, but the results

may not be satisfactory depending on the type of VCR used.

• When the Disc Recorder is connected to several cameras, for example through a multiplexer, all camera inputs must be

synchronized to obtain proper images.
Refer all connection work to qualified service personnel or system installers.

• If you use the WJ-DR200 AV Disc Recorder with a Sequential Switcher that is connected to non-synchronized cameras

(*1) and switches their video output sequentially (*2), recording with the following capture rates is not available:

720

*

480 mode

0.07 sec.

720

*

240 mode

0.03 sec.

*1: Including cameras with VD (Vertical Drive) synchronization.
*2: Without using the camera switching pulse supplied by the WJ-DR200.

Connection with Video Multiplexer

Example: Connection with Video Multiplexer WJ-FS616

Note:

Refer connection with a Video Multiplexer other than the WJ-FS616 to qualified service personnel or system installers.

MULTI SHOT (MODE *)

TIME LAPSE (MODE *)

MANUAL REC ALARM

SERIAL SETUP

Item

VIDEO INPUT

CAPTURE RATE

CAMERA INPUT

SIGNAL TYPE

Parameter

COMPOSITE *1

0.1 sec. or more

A (CAMERA ID ON)

RS-232C (VCR mode) *3

Default Setting

COMPOSITE

S *1

COMPOSITE

0.20 sec.

A (CAMERA ID OFF)

RS-232C

WJ-DR200 System Setup

Cautions:

Noise may appear in the monitor image and the audio may be interrupted under the following circumstances:

• Faulty camera synchronization, causing large frequency deviations between individual cameras
• Picture experiencing abrupt changes in brightness
• Faulty timing in switching input and recording of video signals (for example, a sequential switcher is not used for the

camera switching output of the disc recorder, or switching is out of synchronization due to an alarm condition)

Advertising