V OH = 11 - 13 V (4 700

)

V OL = 0 - 0.6 V (3.0 mA max.)

V OH = 5±0.5 V (200

)

V OL = 0 - 0.6 V (3.0 mA max.)

Alarm
Recover
Output

-47-

General

Power Source:

120 V AC, 60 Hz

Power Consumption:

38 W

Ambient Operating Temperature:

+5°C - +40°C (41°F - 104°F)

Ambient Operating Humidity:

Less than 90 %

Dimensions:

420 (W) x 88 (H) x 350 (D) mm
16-9/16” (W) x 3-7/16” (H) x 13-3/4” (D)

Weight:

7

kg (15.4 lbs.)

Input and Output

Video Input A:

1.0 V[p-p]/75

NTSC Composite Video Signal

with 75

Automatic Termination/Looping through (x1)

Y Signal; 0.714 V[p-p], C Signal; 0.286 V[p-p]/75

S-Video Signal (x1)

Video Input B:

1.0 V[p-p]/75

NTSC Composite Video Signal

with 75

Automatic Termination/Looping through (x1)

Video Output:

1.0 V[p-p]/75

NTSC Composite Video Signal (x1)

Y Signal; 0.714 V[p-p], C Signal; 0.286 V[p-p]/75

S-Video Signal (x1)

Audio Input:

47 k

unbalanced, RCA standard jack, 11 kHz sampling

Audio Output:

600

unbalanced, RCA standard jack

Camera Switching Output:

1 circuit, RCA standard jack

Terminal Board:

Sensor Input: Pulse width 100 ms or more, Normally open or normally closed
selectable
Alarm Input: Pulse width 100 ms or more, Normally open or normally colosed
selectable
Alarm Reset Input: Pulse width 100 ms or more, Low active
Series Record Input: 1 circuit
Time Adjustment Input: Pulse width 100 ms or more, Low active
Alarm Output: Switched by alarm output level selector*

1

Alarm Recover Output: Switched by alarm output level selector, Pulse width 100
ms*

1

LED Monitor Output: 1 circuit (ALARM REC, REC, DISC), 30 V DC 50 mA max.
Buzzer Output: 30 V DC 50 mA max.
System Error Output: 30V DC 50 mA max.
Thermal Error Output: 30 V DC 50 mA max.
Time Adjustment Output: Pulse width 1 s, 30V DC 50 mA max.
Series Record Output: 30 V DC 50 mA max.

Serial Control Port:

Baud Rate; 2 400 - 115 200 bps, Data Bit: 8, Parity Check: None, Start Bit: 1, Stop
Bit: 1, (25-pin D-sub Connector)

Parallel Control:

(25-pin D-sub Connector)

*

1

Alarm Output Level Selector [H]

SPECIFICATIONS

Weight and dimensions shown are approximate.
Specifications are subject to change without notice.

Alarm
Output

V OL

V OH

Alarm

Alarm Output Level Selector [L], 30 V DC 50 mA max.