Water temperature sensor, Caution – Pentair EasyTouch Pool/Spa Control System LX-100EZ User Manual

Page 17

Advertising
background image

Rev. F 3-26-04

17

P/N 520050

WATER TEMPERATURE SENSOR

For use with optional Indoor Control Panel only.
Select a convenient location to mount the Temperature Sensor (model TS-5L) in the plumbing system between
the filter pump and the heater.
Drill a 5/16” diameter hole in the pipe, and insert the Sensor.
Use a screwdriver to open the hose clamp (included). Position clamp over the Sensor, and gently tighten around
the pipe.

CAUTION

Overtightening of clamp can cause deformation of o-ring seal.

Run 2-conductor cable (25 ft. is included with Installation Hardware package) between Sensor location and
low-voltage compartment of LX-100 RF Power/Load Center.

At the LX-100 RF Power/Load Center, strip insulation of both conductors ¼”, and connect to circuit board at
SNS- and SNS+ Screw Terminals. Pay attention color-coding (green conductor connects to SNS-; red conductor
connects to SNS+).

+12

FRZ

AUX1

SPA

GND

SNS+

AUX3

AUX2

SNS-

REMOTE SWITCHES

C

S

P

G H T R

1

2

WATER TEMPERATURE

SENSOR

LX-100 RF POWER/LOAD CENTER

RED

GRN

Advertising