B–5

Host I/O Interfaces

Dataproducts Parallel Interface

This interface allows the printer to operate with controllers designed for

Dataproducts printers. The interface is capable of transferring up to 500,000

characters per second. The maximum cable length from the controller (host

computer) to the printer is 40 feet.

NOTE: Optional adapter cable (p/n 703316–001) and termination resistors

RP1 330

(p/n 101381–331) and RP2 220

(p/n 101381–002) are

required.

Dataproducts Interface Connector Pin Assignments

The printer provides a 36–pin D–shell connector on the rear panel for connection

of a parallel interface cable. This 36–pin connector requires a cable adapter to

convert it to a 50–pin AMP connector for Dataproducts compatibility. Contact

the factory for the adapter (p/n 703316–001). Table B–2 lists the pin assignments

of the Dataproducts cable adapter.

Table B–2. Dataproducts Parallel Interface Pin Assignments (Cable Adapter)

Input Signals

Output Signals

Signal

Pin

Signal

Pin

DATA LINE 1

19

Return

3

READY/FAULT

22

Return

6

DATA LINE 2

20

Return

4

ON LINE/SELECT

21

Return

5

DATA LINE 3

1

Return

2

DATA REQUEST/ACK 23

Return

7

DATA LINE 5

34

Return

18

Interface Verif.

45, 46

DATA LINE 6

43

Return

42

PAPER INST

30

Return

14

DATA LINE 7

36

Return

35

DATA LINE 8

28

Return

44

DATA STROBE

38

Return

37

Advertising