Table 43 current foldback ratings, Figure 42 time until current foldback occurs, Difold – Parker Hannifin 88-021610-01G User Manual

Page 102

Advertising
background image

Parker Hannifin

102 Aries User Guide

DIFOLD

Current Foldback Enable

Type

Drive Configuration

Product Rev

Syntax

<a_>DIFOLD<b>

Aries 1.0

Units

b = enable bit

Range

Ø (disable) or 1 (enable)

Default

1

Response

DIFOLD: <*>Ø

See Also

none

The DIFOLD command enables (1) or disables (Ø) the drive’s current

foldback protection feature. The current foldback feature reduces the drive’s
continuous current output by 20% when sustained current has the potential
to overheat the drive. For the AR-20xE and AR-30xE drives, this feature is
always enabled.

Each drive has the specifications shown in Table 43. Note that current
ratings are for the drive, not for the motor.

AR-01xx

AR-02xx

AR-04xx

AR-08xx

AR-13xx

AR-20xE

AR-30xE

Drive Continuous Current
Rating (100%)

1.0
Arms

1.75
Arms

3.0
Arms

4.5
Arms

6.3
Arms

10
Arms

16
Arms

Max Current Rating

3.0
Arms

5.25
Arms

9.0
Arms

13.5
Arms

14.07
Arms

30
Arms

48
Arms

Max Time at Peak Current
Rating

3.375
sec

3.375
sec

3.375
sec

3.375
sec

8.64
sec

3.375
sec

3.375
sec

Table 43 Current Foldback Ratings

If your drive is operating above its continuous rating, see Figure 42 to predict
the number of seconds until foldback occurs. For example, the graph shows
that at the drive’s peak current rating (300% of continuous), foldback occurs
after 3.375 seconds.

Note:

For model AR-13xx, foldback occurs after 8.64 seconds at its peak

rating (225% of continuous).

Figure 42 Time until current foldback occurs

Advertising