Parker Hannifin

74 Aries User Guide

RS-232/485 Communications

The Aries drive has a single serial port, located on the

DRIVE I

/

O

connector on

the front of the unit. This chapter refers to it as the COM port. The Aries drive
uses ASCII and the RS-232 or RS-485 communication protocols.

Terminal Emulator Configuration

RS-232

RS-485 *

Rx, Tx, Gnd

2-wire plus ground
(Talk+, Talk–, Gnd)

9600 baud

9600 baud

8 data bits

8 data bits

1 stop bit

1 stop bit

No parity

No parity

Full-duplex

Half-duplex

* Twisted pair cabling recommended

(e.g. Belden 9842)

Table 35 Terminal Emulator Configuration for RS-232/485 Communication

Establishing Communications

The 26-pin

DRIVE I

/

O

connector (female D-subminiature) also functions as the

COM port. You can use it with RS-232 or two-wire RS-485 communications.

Figure 35 RS-232/485 Connections

For setup purposes, you can connect a personal computer (PC) directly to
the Aries drive through its COM port. Before attempting to communicate with
the Aries drive, verify your PC’s connector pinout—make sure the cable
connects the following:

• The PC’s transmit terminal (pin 3 of the 9-pin connector) to the

Aries’s receive terminal (pin 25).

• The PC’s receive terminal (pin 2 of the 9-pin connector) to the

Aries’s transmit terminal (pin 26).

• The PC’s ground terminal to the Aries’s ground terminal (pin 24).

You can also use the Aries Drive I/O Dongle (sold separately), which allows
a PC to simultaneously communicate with the Aries drive while also
connected to a controller. For more information, see “RS-232/485 Dongle for
Communications Setup”