104 Aries User Guide

DMODE

Mode

Description

1

Autorun

Rotates the motor at 1 rps/mps. Current is
reduced by 10%.

2

Torque/Force
Control

Allows direct control of rotary motor
torque, or linear motor force.

3

Feedback Alignment Auto-configure for feedback setup.

4

Velocity Control

Allows direct control of rotary or linear
motor velocity.

6

Position Control

Uses 5V Differential compatible (RS-422
logic level compatible) step and direction
control.

7

Reversed Position
Control

Reverses the polarity of the step and
direction signal.

Table 44 Drive Control Mode

Note:

dmodes 6 and 7 are available only on the step and direction versions

of the Aries drive.

DMPSCL

Incoming Pulse Scaling

Type

Drive Configuration

Product Rev

Syntax

<a_>DMPSCL<i>

Aries 2.0

Units

i = multiplier setting

Range

0 to 127

Default

1

Response

DMPSCL: <*>1

See Also

DMODE

,

DMTR

,

DRES

Use the DMPSCL command to scale the incoming pulses for the step and

direction input. A setting of 10 would move the motor 10 encoder pulses for
each input pulse. This command is only valid in

DMODE6

(Position Mode).

DRES command: Added DRES command for step and direction inputs. Input
steps will be scaled to DRES value so DRES steps on the input would

translate to 1 revolution of the motor.

DRES is set to ERES internally if DMPSCL is non-zero for backward
compatibility. DMPSCL should be set to 0 to enable DRES support.

NB: DRES change requires a reset to take effect. DMPSCL works immediately
so the user could use DMPSCL0 to enable DRES support then enable DMPSCL

and have both features working at once.