Table 46 error status, Text based report, Errorl – Parker Hannifin 88-021610-01G User Manual

Page 131

Advertising
background image

Parker Hannifin

Chapter 6 Command Reference 131

Error

Description

E45-Excessive Velocity Error

Commanded velocity. Actual Velocity is greater
than the value set by SMVER.

E46-Hardware Enable

0 = Hardware Enable (Drive I/O Pin 1 and 21)
1 = No Hardware Enable

E47-Low Voltage Enable

No motor power was present when the drive was
enabled.

E48-Control Power Active

The drive is in Control power mode. No motor
power is present.

E49-Alignment Error

The ALIGN command did not complete
successfully. (TPE, THALL)

E50-Flash Error

A problem writing to non-volatile memory exists.
(RFS).

E51-Resolver Error

A problem determining the correct resolver angle
exists. Applies to Arxx-xR models only. Check the
resolver feedback wiring.

E52-Encoder Loss Fault

The drive determined there was loss of feedback.
Check the feedback wiring. (TPE, THALL)

Table 46 Error Status

Text Based Report

ERRORL

Error Log Selection

Type

Error Handling

Product Rev

Syntax

<a_>ERRORL<b><b>...<b><b> (32 bits)

Aries 1.0

Units

b = enable bit

Range

Ø (disable) or 1 (enable)

Default

1111111111111111

Response

ERRORL:

<*>ШШШШ_ШШШШ_ШШШШ_ШШШШ

bit

15

bit Ø

See Also

CERRLG

,

ERROR

,

TERRLG

Use the ERRORL command to choose the conditions that will be included in
the error log. When an error log bit is enabled (ERRORL11...11), the

operating system will respond to a specific execution error by making an
entry in the error log. Each bit corresponds to a different error condition (see
Table 47). To enable or disable a specific bit, the syntax is ERRORL=B.n-b,
where “n” is the error bit number and “b” is either one (1) to enable or zero
(Ø) to disable.

Use the TERRLG command to view the error log. Use the CERRLG command

to clear the error log.

Advertising