Chapter 3 Electrical Installation 53

Relay Operation

Drive Condition

Relay State

Enabled

Closed (conducting)

Faulted

Open

No AC power on L1 and L2*, or drive not
enabled

Open

* Mains Control power on C1 and C2 does not affect the relay. With mains power applied

to C1 and C2, the relay remains open if AC power is not applied to the L1 and L2
terminals.

Table 20 Brake Relay Operation

Relay Specifications

Relay Type .............................................. Solid State Relay

Normally open

Relay Maximum Rating........................... 1 Amp at 24 VDC

Warning —

Do not exceed the ratings of the brake relay. If required,

control a suitable external relay with this relay to meet your power
requirements.