Error codes, Igp/pgl emulation error codes – Printronix LQH-HWTM User Manual

Page 261

Advertising
background image

261

6

Error Codes

IGP/PGL Emulation Error Codes

The IGP provides coded error messages to assist in “debugging” programs.
The printer will print an error message number and the program line which
contains the error when an error is detected. To help determine exactly where
the error occurred, use the following debug command sequence:

(CC)CREATE;/

FORM NAME

The slash (/) places the IGP in a debug mode, and the program prints, line by
line, with the error number and message printed below the specific error in the
program. The error-free portions of the form will print following the program.
After correcting the error(s), print the file again. When the errors have been
corrected, delete the slash. A sample debug listing is shown in “Solving
Program Errors” on page 248.

In the Execute mode, that part of the form which was correctly defined and
stored during the Create mode will print, including any dynamic data and
overlay text which was accepted before the error occurred. Sections
containing errors must be corrected before storage in the Directory can take
place. Any error messages will print following the printed form, and
processing will continue in the Normal mode.

In the Create Form or Create Logo mode, any error messages will print first,
followed by that part of the form/logo which was correctly defined. Incorrectly
defined elements are excluded from the form/logo.

The error codes are broken down into categories. In each category, the
number preceding each error message is the actual error code reported by
the printer, and the error shown in bold is the error message printed.