Command Codes

Comments The IGP/PGL configuration parameters available are defined in

your

User’s Guide.

Any or all parameters can be used within one CONFIG
command, and they can be listed in any order. List each
parameter;value on a separate line, terminating with the END
command. Default configuration values can be reset using the
CONFIG command.

Parameters not followed by a value, and parameters followed by
any non-zero value are interpreted as “true” or “enabled” values.
For carriage return and line feed definitions, a zero value does
not change the data stream. However, for non-zero values, a
carriage return character or line feed character will be interpreted
as a carriage return plus a line feed.

Parameters not listed in this command remain unchanged. If a
parameter error is detected for parameters other than 0 or 1 (i.e.,
SFCC, Top/Bottom Margin, Left Margin), the value will default to
the current configuration from disk/flash.

Example 1 The following command enables IGP/PGL Auto Wrap, disables

Auto Eject, and selects 6 lpi printing.

~CONFIG
AUTO WRAP;1
AUTO EJECT;0
LPI;6
END

Example 2 The following command resets all control panel IGP/PGL

configuration parameters back to default values.

~CONFIG
RESET
END