Email alert tab field descriptions – Perle Systems 5500161-40 User Manual

Page 119

Advertising
background image

119

Serial Port Profiles

Email Alert Tab Field Descriptions

Email notification can be set at the Server and/or serial port levels. You can set unique email
notifications for each serial port because the person who administers the IOLAN might not be the
same person who administers the serial device(s) attached to the IOLAN port. Therefore, email
notification can be sent to the proper person(s) responsible for the hardware.

The following event triggers an email notification on the

Serial Port

for the specified

Level

:

z

DSR signal loss, Warning Level

z

I/O alerts, Critical Level

Configure the following parameters:

Enable Port Email
Alert

Use System Email
Alert Settings

Level

To

Subject

From

Reply To

Outgoing Mail
Server (SMTP)

Enable/disable email alert settings for this serial port.

Default: Disabled

Determines whether you want the

Serial Port

to inherit the

Email Alert

settings

from the

System Email Alert

configuration. If this is enabled,

System

and

Serial Port

notification events will have the same

Email Alert

setting.

Default: Enabled

Choose the event level that triggers an email notification.

Data Options: Emergency, Alert, Critical, Error, Warning, Notice, Info,
Debug

Default: Emergency

An email address or list of email addresses that will receive the email
notification.

A text string, which can contain spaces, that will display in the

Subject

field of

the email notification.

This field can contain an email address that might identify the IOLAN name or
some other value.

The email address to whom all replies to the email notification should go.

The SMTP host (email server) that will process the email notification request.
This can be either a host name defined in the IOLAN host table or the SMTP
host IP address.

Advertising