Field descriptions – Perle Systems 5500161-40 User Manual

Page 259

Advertising
background image

259

Channels

Field Descriptions

Configure the following parameters:

Description

Provide a description of the channel, making it easier to identify.

Data Options: Maximum 20 characters, including spaces

Output Mode

When selected, the channel will drive the line (output). The internal jumpers
must match the software configuration, so if you change this setting to

Output

Mode

, you will have to also change the internal hardware jumpers.

Default: Disabled

Type

Specify the type of digital output.

Data Options:

z

Sink—Specifies that the channel will be grounded when active.

z

Source—Specifies that the channel will provide voltage when active.

z

Sink and Source—Specifies that channel will be grounded when it is
inactive and will provide voltage when it is active.

Default: Sink

Output

Specify how the channel output will be handled.

Data Options:

z

Manual—You must manually manipulate the channel output.

z

Pulse—Activates and deactivates the channel output activity in intervals
after it is manually activated.

z

Inactive-to-Active Delay—The channel output will remain inactive for
the specified time interval after it is manually started.

z

Active-to-Inactive Delay—The channel output will go inactive after the
specified time interval after it is manually started.

Default: Manual