Channels

262

IOLAN SDS/SCS/STS/MDC User’s Guide, Version 4.0

Field Descriptions

Configure the following parameters:

Description

Provide a description of the channel, making it easier to identify.

Data Options: Maximum 20 characters, including spaces

Output

Specify how the channel output will be handled.

Data Options:

z

Manual—You must manually manipulate the channel output.

z

Pulse—Activates and deactivates the channel output activity in intervals
after it is manually activated.

z

Inactive-to-Active Delay—The channel output will remain inactive for
the specified time interval after it is manually started.

z

Active-to-Inactive Delay—The channel output will go inactive after the
specified time interval after it is manually started.

Default: Manual

Pulse Mode

When

Output

is set to

Pulse

, you can specify the manner of the pulse.

Data Options:

z

Continuous—Continuously pulses active and inactive.

z

Count—Pulses an active/inactive sequence for the specified number of
times.

Default: Continuous

Pulse Count

The channel output will pulse for the specified number of times; each count
consists of an active/inactive sequence.

Default: 1

Inactive Signal
Width

How long the channel will remain inactive during pulse mode.

Range: 1-9999 x 100 ms

Default: 1 (100 ms)