Serial Port Profiles

Trigger

When the trigger condition is met, triggers the specified alarm action.

Data Options:

z

Disabled—No alarm settings. This is the default.

z

Inactive—When the expected Digital input is active, going inactive will
trigger an alarm.

z

Active—When the expected Digital input is inactive, going active will
trigger an alarm.

Default: Disabled

Auto Clear Mode

When enabled, automatically clears the alarm when the trigger condition
changes; for example, if the

Trigger

is

Inactive

and the alarm is triggered, once

the input becomes active again, the alarm will automatically be cleared

Default: Enabled

Manual Clear
Mode

When enabled, a triggered alarm must be manually cleared.

Default: Disabled

Email

When enabled, sends an email alert to an email account(s) set up in the

System

settings when an alarm is triggered or cleared. The email alert data includes the
severity level and the value that caused the alarm to trigger or clear. The

Email

Alert

is associated with

Level Critical

.

Default: Disabled

Syslog

When enabled, sends a message to syslog when an alarm is triggered or
cleared. The syslog entry includes the severity level and the value that caused
the alarm to trigger or clear. The syslog message is associated with

Level

Critical

.

Default: Disabled

SNMP

When enabled, sends an SNMP trap when an alarm is triggered or cleared. The
trap consists of the severity level and whether the alarm was triggered or
cleared.

Default: Disabled