Serial Port Profiles

174

IOLAN SDS/SCS/STS/MDC User’s Guide, Version 4.0

General Tab Field Descriptions

Configure the following parameters:

Mode

Destination Slave
IP Mappings
Button

Advanced Slave
Settings Button

UID Range

Modbus/RTU

Modbus/ASCII

Append CR/LF

Specify how the Modbus Gateway is defined on the serial port.

Data Options:

z

Modbus Master—Typically, the Modbus Master is connected to the
Serial Port and is communicating to Modbus Slaves on the network.

z

Modbus Slave—Typically, the Modbus Master is accessing the IOLAN
through the network to communicated to Modbus Slaves connected to the
IOLAN’s Serial Ports.

Default: Modbus Master Gateway

Click this button to launch the Destination Slave IP Settings window, where
you can configure the TCP/Ethernet Modbus Slaves that the Modbus Master on
the Serial Port will communicate with.

Click this button to configure global Modbus Slave settings.

You can specify a range of UIDs (1-247), in addition to individual UIDs.

Field Format: Comma delimited; for example, 2-35, 50, 100-103

Select this option when the Modbus/RTU protocol is being used for
communication between the Modbus Master and Slave.

Default: Enabled

Select this option when Modbus/ASCII protocol is being used for
communication between the Modbus Master and Slave.

Default: Disabled

When

Modbus/ASCII

is selected, adds a CR/LF to the end of the transmission;

most Modbus devices require this option.

Default: Enabled