Wiring up a dhv unit – Perle Systems 5500161-40 User Manual

Page 48

Advertising
background image

Powering Up the IOLAN

48

IOLAN SDS/SCS/STS/MDC User’s Guide, Version 4.0

Wiring up a DHV unit

Terminal #

Description

Usage

1

Normally Open Normally Open is a fail-safe relay connection. Use this with the

Common terminal to act as switch contacts that remain open when
the unit is powered off or in a failure state.

2

Common

Common is a fail-safe relay connection. Use this terminal in
conjunction with the Normally Open or Normally Closed terminals.

3

Normally
Closed

Normally Closed is a fail-safe relay connection. Use this with the
Common terminal to act as switch contacts that remain closed
when the unit is powered off or in a failure state.

4

Chassis Ground Chassis Ground must be connected to "Equipment Ground" for DC

installations or "Safety Ground" for AC installations.

5

+ / L (source 1) + / L (Source 1) is connected to the positive (+) input for DC

sources or to the Live input for AC sources. Use with partner
terminal -/N(Source 1).

6

- / N(source 1)

- / N (Source 1) is connected to the negative (-) input for DC
sources or to the Neutral input for AC sources. Use with partner
terminal +/L(Source 1).

7

+ / L (source 2) + / L (Source 2) is connected to the positive (+) input for DC

sources or to the Live input for AC sources. Use with partner
terminal -/N(Source 2).

8

- / N(source 2)

- / N (Source 2) is connected to the negative (-) input for DC
sources or to the Neutral input for AC sources. Use with partner
terminal +/L(Source 2).

E

Earth Ground

Earth Ground is a connection to the chassis that can be used for
earth bonding.

NOTES: