Starting a payload loopback, Procedure – Paradyne 3161-B3 User Manual

Page 126

Advertising
background image

4. Maintenance

4-24

February 2001

3160-A2-GB21-90

Starting a Payload Loopback

The Payload Loopback command (PLB) loops the received signal on the network
interface back to the network. The signal is looped back as close to the DTE
Drop/Insert (DSX-1) port as possible (after it has passed through the framing
circuitry of the DSU/CSU). Framing CRCs and BPVs are corrected.

Procedure

To perform a Payload loopback:

1. From the top-level menu screen, select Test.

2. From the Test screen, select Lpbk.

3. From the Loopback screen, select PLB.

Test Started

appears on Line 2. If a Payload loopback is already in

progress, the

Already Active

message appears. If an invalid combination

of loopbacks is in progress, the error message

Invld Test Combo

appears

(see

Table 4-8, Valid Loopback Combinations

, for valid loopback test

combinations).

496-14316-02

CSU

DSU

NETWORK

INTERFACE

DTE

(DSX-1)

ALL 1s

PLB

PORT 1

PORT 2

ALL 1s

ALL
1s

F1

F2

F3

Test:
Rlpbk Lpbk Ptrns

F1

F2

F3

Loopback:
Abort LLB PLB

Advertising
This manual is related to the following products: