3. Operation

3-62

February 2001

3160-A2-GB21-90

5. Select User.

6. Press F1 (Next) until the Com Port configuration option appears.

7. Select Enab to enable the COM port for the carrier-mounted DSU/CSU.

The carrier COM port provides the following functionality:

T

If configured for ASCII, only one ASCII device may be used for the carrier. (If
two COM ports are configured for ASCII, neither will work.)

T

If configured for Mgmt, each device in the carrier can support an Mgmt COM
port; however, each Mgmt COM port must be connected to a different subnet.
To facilitate IP data routing, the device with the closest link to the SNMP
manager or Telnet client should be configured as the IP Bus Master.

T

If configured for either ASCII or Mgmt, the carrier COM port may be configured
to control an external device (e.g., modem, x.25 PAD) through the use of AT or
user-specified commands.

The set of valid characters for control of the carrier external COM port device is as
follows:

T

The numbers: 0–9

T

The lowercase letters: a–z

T

The uppercase letters: A–Z

T

The space (“ ”) character

T

The ASCII symbols (in ascending order, based on the ASCII code)

T

The End Of Line (EOL) symbol:

T

The caret (“^”) control character is used to select non-printable ASCII
characters. The caret “^” must be followed by one character which together
form the control sequence.

Table 3-7, Control Sequence

, defines all of the

available control sequences.

F1

F2

F3

Edit:
Chan Gen User

F1

F2

F3

Com Port:
Next Enab Disab

Advertising
This manual is related to the following products: