Paradyne 3161-B3 User Manual

Page 240

Advertising
background image

E. SNMP MIB Objects

E-26

February 2001

3160-A2-GB21-90

Where these object identifiers are defined as follows:

T

testLoopDTLB – OBJECT IDENTIFIER ::= [wellKnownTests 2]

T

testMonQRSS – OBJECT IDENTIFIER ::= [wellKnownTests 3]

T

testMon511 – OBJECT IDENTIFIER ::= [wellKnownTests 4]

T

testSendQRSS – OBJECT IDENTIFIER ::= [wellKnownTests 5]

T

testSend511 – OBJECT IDENTIFIER ::= [wellKnownTests 6]

T

testSendV54Up – OBJECT IDENTIFIER ::= [wellKnownTests 7]

T

testSendV54Down – OBJECT IDENTIFIER ::= [wellKnownTests 8]

T

testSendFT1Up – OBJECT IDENTIFIER ::= [wellKnownTests 9]

T

testSendFT1Down – OBJECT IDENTIFIER ::= [wellKnownTests 10]

Generic Interface Test Table – “ifExtnsTestResult” Object
(ifExtnsTestEntry 5)

This object contains the result of the most recently requested test. Only the
following values are supported by the DSU/CSU.

T

none(1) – No test currently active.

T

inProgress(3) – A test is currently in progress.

T

notSupported(4) – The requested test is not supported.

T

unAbleToRun(5) – The requested test cannot run due to the state of the unit.

Generic Interface Test Table – “ifExtnsTestCode” Object
(ifExtnsTestEntry 6)

This object contains a code that contains more specific information on the test
result. This object is defined as an object identifier. Only the following values are
supported by the DSU/CSU.

T

none – No further information is available. Used for the send pattern/code and
loopback tests.

T

inSyncNoBitErrors – A monitor pattern (QRSS or 511) test has synchronized
on the pattern and has not detected any bit errors.

T

inSyncWithBitErrors – A monitor pattern (QRSS or 511) test has synchronized
on the pattern and has detected bit errors.

T

notInSync – A monitor pattern (QRSS or 511) test has not synchronized on
the requested pattern.

Advertising
This manual is related to the following products: