Chassis cooling, Environmental – National Instruments NI PXIe-1075 User Manual

Page 45

Advertising
background image

Appendix A

Specifications

NI PXIe-1075 User Manual

A-4

ni.com

Chassis Cooling

Module cooling system...........................Forced air circulation (positive

pressurization) through three
165 cfm fans with High/Auto
speed selector

Slot airflow direction ..............................Bottom of module to top of

module

Module cooling intake ............................Bottom rear of chassis

Module cooling exhaust..........................Along both sides and top of

chassis

Power supply cooling system .................Forced air circulation through

two integrated fans

Power supply cooling intake...................Right side of chassis

Power supply cooling exhaust ................Left side of chassis

Clearance for intake/exhaust vents .........1.75 in (44.45 cm) for top

and side vents
3.00 in (76.20) for back vents

Maximum fan cleaning interval..............6 months

Fan filter material ...................................30 ppi, 3/32 in (0.24 cm)

polyurethane foam. Refer to the

Cleaning the Fan Filters

section

of Chapter 3,

Maintenance

, for

more information.

Environmental

Maximum altitude...................................2,000 m (800 mbar)

(at 25 °C ambient)

Pollution Degree .....................................2

For indoor use only.