There are six dual-color LED indicators on the front panel of the chassis.
Four of the LEDs indicate the status of voltage supply regulation (+3.3 V,
5 V, +12 V, –12 V). The FAN LED indicates the operational status of the
fan. The TEMP LED indicates whether the chassis is maintaining a proper
operating temperature, or whether there is an over-temperature condition.
The operating temperature of the chassis should not exceed 60 °C.

Remote Voltage, Temperature, and Fan Monitoring

The PXI-1056 chassis supports remote voltage, temperature, and fan
monitoring through a RS-232 9-pin D-sub connector located on the rear
panel. Table 2-1 shows the pinout of the 9-pin D-sub connector.

Caution

Use the rear-panel 9-pin D-sub connector to connect to an RS-232-capable

device. Do not use the connector to supply power to external devices, or damage to the
chassis may result.

Table 2-1. Voltage Monitoring Connector Pinout

D-sub Pin

Signal

1

Ground

2

Receive data input

3

Request to send, input

4

Transmit data, output

5

Clear to send, output

6

Reserved

7

Reserved

8

Reserved

9

Reserved