National Instruments NI PXI-1056 User Manual
Page 28

Chapter 2
Installation and Configuration
© National Instruments Corporation
2-13
Request for All Status
Note
Voltage units are in V
DC
, and temperature units are in degrees Celsius.
Command
Response
Description
SA
<CR><LF>MONITOR,
209-2xxx-Cxx-00 Rx
<CR><LF><CR><LF>
Header information
SP:PS: x <CR><LF>
Power supply status, x = OK or FAIL
ST:T1: x <CR><LF>
Temperature sensor #1, x = OK or FAIL
ST:T2: x <CR><LF>
Temperature sensor #2, x = OK or FAIL
ST:T3: x <CR><LF>
Temperature sensor #3, x = OK or FAIL
SV:V1: x<CR><LF>
+3.3VDC supply, x = OK or FAIL
SV:V2: x<CR><LF>
+5VDC supply, x = OK or FAIL
SV:V3: x<CR><LF>
+12VDC supply, x = OK or FAIL
SV:V4: x<CR><LF>
–12VCDC supply, x = OK or FAIL
SV:V5: x<CR><LF>
+5VDC VSB supply, x = OK or FAIL
SF:F1: x<CR><LF>
Fan #1, x = OK or FAIL
SF:F2: x<CR><LF>
Fan #2, x = OK or FAIL
SF:F3: x<CR><LF>
Fan #3, x = OK or FAIL
SF:F4: x<CR><LF>
Fan #4, x = OK or FAIL