Backplane, 10 mhz system reference clock (10 mhz ref) – National Instruments NI PXI-1056 User Manual

Page 42

Advertising
background image

Appendix A

Specifications

NI PXI-1056 User Manual

A-6

ni.com

Backplane

Size .........................................................3U/6U-sized; one 3U system slot

(with three system expansion
slots) and 17 3U peripheral slots,
or any combination up to
7 6U cards and 3U cards.
Compliant with IEEE 1101.10
mechanical packaging.
PXI Hardware Specification,
Revision 2.2
compliant.
Accepts both PXI and
CompactPCI (PICMG 2.0 R 3.0)
3U and 6U modules.

V(I/O)

1

....................................................+5 V

Backplane bare-board material ...............UL 94 V-0 Recognized

Backplane connectors .............................Conforms to IEC 917 and

IEC 1076-4-101, and are
UL 94 V-0 rated

10 MHz System Reference Clock (10 MHz REF)

Maximum clock skew
between slots...........................................250 ps

Built-in 10 MHz clock

Accuracy..........................................±25 ppm (guaranteed over the

operating temperature range)

Maximum jitter................................5 ps RMS in 10 Hz to 1 MHz

range

External clock sources

Connectors.......................................Slot 2 J2 (pin D17; refer to

Table B-4,

P2 (J2) Connector

Pinout for the Star Trigger Slot

)

Input frequency................................10 MHz ±100 ppm or better

Input amplitude

Slot 2 ........................................5 V or 3.3 V, 10 MHz TTL signal

1

V(I/O) is connected to the +5 V DC power plane, so the same specs apply to V(I/O) and +5 V.