Chapter 1

Getting Started

NI PXI-1056 User Manual

1-2

ni.com

If you are missing any of the items listed in Table 1-1, or if you have the
incorrect AC power cable, contact National Instruments.

Key Features

The PXI-1056 combines a high-performance 18 slot 3U-sized (or 4 3U and
7 6U slot) PXI backplane with a high-output power supply and a structural
design that has been optimized for maximum usability in a wide range of
applications. The modular design of the chassis ensures a high level of
maintainability, resulting in a very low mean time to repair (MTTR). The
PXI-1056 complies with the PXI Hardware Specification, Revision 2.2
(32-bit), offering advanced timing and synchronization features.

Note

The PXI-1056 chassis only complies with the 32-bit/33 MHz operational specs of

the PXI Hardware Specification.

The key features of the PXI-1056 include the following:

PXI and CompactPCI (PICMG 2.0 R 3.0) module compatibility

4 3U-sized and 7 6U-sized dual-stack capable slots

Universal AC input: automatic voltage and frequency ranging

Over-current protection through push-reset circuit breaker (no
AC-input fuses to replace)

Removable modular power-supply shuttle

Remote voltage, temperature, and fan monitoring through a rear-panel
RS-232 connector

On/Off (Standby) power switch on the front panel for easy access

Table 1-1. AC Power Cables

Power Cable

Reference Standards

Standard 120 V (USA)

NEMA 5-15

Switzerland 220 V

SEV

Australia 240 V

AS C112

Universal Euro 230 V

CEE (7), II, IV, VII IEC83

North America 240 V

NEMA 6-15

United Kingdom 230 V

BS 1363/IEC83