Preinstallation requirements

Standard 1.0

34

CallPilot

Inspecting the server interior

Introduction

You should perform a visual inspection for loose components, foreign
matter, or shipping damage inside the server.

Protective foam

The server is shipped with protective foam to prevent damage during
shipping. You must remove the foam before you inspect the server and
continue with the installation. The foam can be stored for future use in case
you need to ship the server back to the distributor or to Nortel Networks.

To remove protective foam and inspect the server interior

1 Carefully remove the foam from inside the chassis.

2 Ensure that all the cards are fully seated on the baseboard.

3 Check for any loose wires or foreign objects, such as loose screws,

inside the chassis.

.

CAUTION

Risk of equipment damage

When working with interior components, use an ESD wrist
strap to protect static-sensitive components.

.

CAUTION

Risk of equipment damage

The server can be damaged if the protective foam is not
removed and the server is powered up. Do not power up the
server while the protective foam is in the server.