Installing the server and connecting the peripheral devices

Standard 1.0

54

CallPilot

To connect the server to power

1 Plug the server’s AC power cord into the server’s rear panel.

2 Plug the other end of the server’s AC power cord into a properly

grounded power outlet or power bar.

To start the server

1 Press the server’s power switch to start the server.

2 Observe the Power-On Self-Test (POST) and initialization messages on

the monitor.

3 When the following menu appears on the monitor, select option 1 to boot

Windows NT:

Select one of the following:

---------------------------

1 Windows NT 4.0 Server (Default within 30 secs)

2 Windows NT 4.0 Server (VGA mode)

Choose an option[1,2]?1

The Windows NT startup sequence begins.

4 Ensure that the Windows NT logon window appears on the monitor.

Note: If the Windows NT logon window does not appear, refer to Part 5
of the CallPilot Installation and Configuration binder for troubleshooting
instructions.

.

CAUTION

Risk of hardware failure

The power outlets that are used by the CallPilot server and its
peripheral devices must be connected to the same ground
reference as the one used by the Meridian 1 switch or
Succession CSE 1000 system with MGate cards connected to
the CallPilot server. If this requirement is not met, power
transients can cause hardware failure.