Installing the server and connecting the peripheral devices

Part 2: 702t Server Hardware Installation

47

4 Connect an RJ-45 network cable from the ELAN hub to the ELAN

connector on the server.

Note: The ELAN hub is optional if you use a cross-over network cable to
make a direct point-to-point connection from the server to the switch.
However, if you choose to establish a direct point-to-point ELAN
connection, no other device can connect to the ELAN.

5 At the switch, connect the ELAN network cable to an MAU (Ethernet)

transceiver. Then complete the connection from the transceiver to the
switch.

What’s next?

.

DANGER

Risk of fire hazard

MAU model NTRH9069 is not suitable for installation in
ducts, plenums, or other spaces used for environmental air. Do
not install it above a false ceiling or below a raised floor,
unless it can be confirmed that these spaces are not used to
convey environmental air.

IF the server will

THEN

be connected to a CLAN

continue with page 48.

not be connected to a CLAN

continue with installing the software
feature key adapter (dongle). See page
50.