Pca9665, Nxp semiconductors – NXP Semiconductors PCA9665 User Manual

Page 76

Advertising
background image

PCA9665_2

© NXP B.V. 2006. All rights reserved.

Product data sheet

Rev. 02 — 7 December 2006

76 of 91

NXP Semiconductors

PCA9665

Fm+ parallel bus to I

2

C-bus controller

[1]

Minimum SCL clock frequency is limited by the bus time-out feature, which resets the serial bus interface if either SDA or SCL is held
LOW for a minimum of 25 ms. Disable bus time-out feature for DC operation.

[2]

t

VD;ACK

= time for Acknowledgement signal from SCL LOW to SDA (out) LOW.

[3]

t

VD;DAT

= minimum time for SDA data out to be valid following SCL LOW.

[4]

C

b

= total capacitance of one bus line in pF.

[5]

A master device must internally provide a hold time of at least 300 ns for the SDA signal (refer to the V

IL

of the SCL signal) in order to

bridge the undefined region SCL’s falling edge.

[6]

The maximum t

f

for the SDA and SCL bus lines is specified at 300 ns. The maximum fall time for the SDA output stage t

f

is specified at

250 ns. This allows series protection resistors to be connected between the SDA and the SCL pins and the SDA/SCL bus lines without
exceeding the maximum specified t

f

.

[7]

Input filters on the SDA and SCL inputs suppress noise spikes less than 50 ns.

Table 51.

I

2

C-bus frequency and timing specifications

All the timing limits are valid within the operating supply voltage and ambient temperature range; V

DD

= 2.5 V

±

0.2 V and

3.3 V

±

0.3 V; T

amb

=

40

°

C to +85

°

C; and refer to V

IL

and V

IH

with an input voltage of V

SS

to V

DD

.

Symbol

Parameter

Conditions

Standard-mode

I

2

C-bus

Fast-mode I

2

C-bus

Fast-mode Plus

I

2

C-bus

Unit

Min

Max

Min

Max

Min

Max

f

SCL

SCL clock frequency

[1]

0

100

0

400

0

1000

kHz

t

BUF

bus free time between a
STOP and START
condition

4.7

-

1.3

-

0.5

-

µ

s

t

HD;STA

hold time (repeated)
START condition

4.0

-

0.6

-

0.26

-

µ

s

t

SU;STA

set-up time for a
repeated START
condition

4.7

-

0.6

-

0.26

-

µ

s

t

SU;STO

set-up time for STOP
condition

4.0

-

0.6

-

0.26

-

µ

s

t

HD;DAT

data hold time

0

-

0

-

0

-

ns

t

VD;ACK

data valid acknowledge
time

[2]

0.05

3.45

0.05

0.9

0.05

0.45

µ

s

t

VD;DAT

data valid time

[3]

50

-

50

-

50

-

ns

t

SU;DAT

data set-up time

250

-

100

-

50

-

ns

t

LOW

LOW period of the SCL
clock

4.7

-

1.3

-

0.5

-

µ

s

t

HIGH

HIGH period of the SCL
clock

4.0

-

0.6

-

0.26

-

µ

s

t

f

fall time of both SDA and
SCL signals

[5][6]

-

300

20 + 0.1C

b

[4]

300

-

120

ns

t

r

rise time of both SDA and
SCL signals

-

1000

20 + 0.1C

b

[4]

300

-

120

ns

t

SP

pulse width of spikes that
must be suppressed by
the input filter

[7]

-

50

-

50

-

50

ns