NetComm IP DSLAM NCT480 User Manual

Page 72

Advertising
background image

NCT480 IP DSLAM User Guide

YML856 Rev3



www.netcomm.com.au

Add ethernet Interface

NCT480 IP-DSLAM supports two Ethernet interfaces and one management port (Ethernet port-3). The IP
address is only for management purpose and each Ethernet interface can be applied with its IP address.

Figure 4-13 Add Ethernet Interface Dialog

Network type ‘downlink’ is for system stacking. Ethernet ports that are not used for DSLAM system
management purpose do not need to be assigned with an IP address.

Beware when select on the ‘Non IP’ option and ‘Delete’ button, the management connection to that particular Ethernet port may be loss
due to those setting.

Item

Description

Select an ethernet port to add

Select the Ethernet port from pull down menu.

Network Type

This specifies the type of the Ethernet interfaces. The uplink is towards the Network
side (2 at most) and downlink is towards the physical interface connected to the slave
device. For uplink type, IP address can not be null, if ‘Is use DHCP’ is false.

Use DhCP

The Ethernet interface will request an IP Address to be assigned by a DHCP Server in
the network.

Non-IP

Select Non IP to restrict the IP management activity.

IP address & netmask

IP Address

This specifies the network IP address of given Ethernet interface, this IP address use
for only system management.

Valid values: Any valid class A/B/C address

Net Mask

This specifies the network mask configured for the interface.

Valid values: 255.0.0.0 ~ 255.255.255.255

Table 4-10 Creating the Ethernet Port

Advertising