Figure 8-2. ni 6238/6239 pfi output circuitry, Using pfi terminals as timing input signals, Using pfi terminals as timing input signals -2 – National Instruments NI 6238 User Manual

Page 107

Advertising
background image

Chapter 8

PFI

NI 6238/6239 User Manual

8-2

ni.com

Figure 8-2. NI 6238/6239 PFI Output Circuitry

When a terminal is used as a timing input or output signal, it is called PFI x
(where x is an integer from 0 to 9). When a terminal is used as a static digital
input or output, it is called P0.x or P1.x.

The voltage input and output levels and the current drive levels of the PFI
signals are listed in the NI 6238/6239 Specifications.

Using PFI Terminals as Timing Input Signals

Use PFI <0..5> terminals to route external timing signals to many different
M Series functions. Each input PFI terminal can be routed to any of the
following signals.

AI Convert Clock

AI Sample Clock

AI Start Trigger

AI Reference Trigger

AI Pause Trigger

AI Sample Clock Timebase

AO Start Trigger

AO Sample Clock

AO Sample Clock Timebase

AO Pause Trigger

Counter input signals for either counter—Source, Gate, Aux,
HW_Arm, A, B, Z

Most functions allow you to configure the polarity of PFI inputs and
whether the input is edge or level sensitive.

Timing Signals

PFI <6..9>/P1.<0..3>

Static DO

Buffer

Isolation

Barrier

Digital

Isolators