Chapter 4

Analog Input

© National Instruments Corporation

4-21

NI 6238/6239 User Manual

Figure 4-13. Single External Signal Driving ai/SampleClock and ai/ConvertClock

Simultaneously

AI Convert Clock Timebase Signal

The AI Convert Clock Timebase (ai/ConvertClockTimebase) signal is
divided down to provide on of the possible sources for ai/ConvertClock.
Use one of the following signals as the source of
ai/ConvertClockTimebase:

ai/SampleClockTimebase

20 MHz Timebase

ai/ConvertClockTimebase is not available as an output on the I/O
connector.

AI Hold Complete Event Signal

The AI Hold Complete Event (ai/HoldCompleteEvent) signal generates a
pulse after each A/D conversion begins. You can route
ai/HoldCompleteEvent out to any output PFI <6..9> or RTSI <0..7>
terminal.

The polarity of ai/HoldCompleteEvent is software-selectable, but is
typically configured so that a low-to-high leading edge can clock external
AI multiplexers indicating when the input signal has been sampled and can
be removed.

• One External Signal Driving Both Clocks

ai/SampleClock

ai/ConvertClock

Sample #1 Sample #2 Sample #3

1 2 3

0

1 2 3

0