Nortel Networks 8005DC User Manual

Page 77

Advertising
background image

Installing and replacing a module

77

— To remove a module from an active system, you must disable the

module before you remove it. Disabling the slot before removing the
module provides a clean disconnect from all services.

The following procedure includes directions for disabling the module.

— If you remove an 8672ATME, 8672ATMM, or 8683POSM module

from an operating switch without turning off the chassis power and
the module you insert has the same type MDAs installed as the
module that you removed, the system saves the configuration.

— If you remove an 8672ATME, 8672ATMM, or 8683POSM module

from an operating switch without turning off the chassis power
and the module you insert has different MDAs installed than the
module that you removed, you must reconfigure the module. Nortel
recommends that you save the original configuration in a file for
future use.

— If you replace a module with a different type module, the system

discards the configuration of the old ports and adds the new ports to
either the default VLAN or a null VLAN, depending on the operating
mode of the switch.

— If you save the configuration in nonvolatile random access memory

(NVRAM), turn off the switch, replace a module with a different
module type, and turn the system on again, the system discards
the configuration of the old ports and adds new ports to either the
default VLAN or an unassigned VLAN, depending on the operating
mode of the switch.

— If you replace an 8691omSF or 8692omSF module, all the other

modules in the chassis reset and revert to their saved configuration
settings. If you did not save the configuration settings for a module,
the module reverts to its factory default settings.

Procedure steps

Step

Action

1

Connect to the Metro Ethernet Routing Switch 8600 command line
interface (CLI) using the management console port.

2

To disable the slot of the module that you are removing, enter the
following command. Specify the slot number for <slotnum>.

conf slot <slotnum> state disable

3

Confirm that the module is disabled.

The online LED on the front panel module is amber when the I/O
module is disabled.

Nortel Metro Ethernet Routing Switch 8600

Installation — Modules

NN46220-306

02.02

Standard

4.2

7 July 2008

Copyright © 2005-2007, Nortel Networks

.