National Instruments PC-DIO-24/PnP User Manual

Page 28

Advertising
background image

Chapter 3

Signal Connections

© National Instruments Corporation

3-5

PC-DIO-24/PnP User Manual

Digital output specifications (referenced to GND):

Output logic high voltage

3.7 V min

5.0 V max

(I

ol

= –2.5 mA)

Output logic high voltage

2.7 V min

5.0 V max

(I

oh

= –4 mA)

Output logic low voltage

0 V min

0.4 V

(I

ol

= 2.5 mA)

Output logic low voltage

0 V min

0.5 V

(I

ol

= 4 mA)

Figure 3-2 depicts signal connections for three typical digital I/O
applications.