Mode 1 output timing, Figure 3-6. mode 1 timing specification for output, Mode 1 output timing -13 – National Instruments PC-DIO-24/PnP User Manual

Page 36: Figure 3-6

Advertising
background image

Chapter 3

Signal Connections

© National Instruments Corporation

3-13

PC-DIO-24/PnP User Manual

Mode 1 Output Timing

The following figure illustrates the timing specifications for an output
transfer in mode 1.

Figure 3-6. Mode 1 Timing Specification for Output Transfers

Name

Description

Minimum

Maximum

T1

WR* = 0 to INTR = 0

250

T2

WR* = 1 to output

200

T3

WR* = 1 to OBF* = 0

150

T4

ACK* = 0 to OBF* = 1

150

T5

ACK* pulse width

100

T6

ACK* = 1 to INTR = 1

150

All timing values are in nanoseconds.

T2

T3

WR*

OBF*

INTR

DATA

T4

T6

T5

ACK*

T1

Advertising