Mode 1 input timing, Figure 3-5. mode 1 timing specification for input, Mode 1 input timing -12 – National Instruments PC-DIO-24/PnP User Manual
Page 35: Figure 3-5
Advertising

Chapter 3
Signal Connections
PC-DIO-24/PnP User Manual
3-12
© National Instruments Corporation
Mode 1 Input Timing
The following figure illustrates the timing specifications for an input
transfer in mode 1.
Figure 3-5. Mode 1 Timing Specification for Input Transfers
Name
Description
Minimum
Maximum
T1
STB* pulse width
100
—
T2
STB* = 0 to IBF* = 1
—
150
T3
Data before STB* = 1
20
—
T4
STB* = 1 to INTR = 1
—
150
T5
Data after STB* = 1
50
—
T6
RD* = 0 to INTR = 0
—
200
T7
RD* = 1 to IBF = 0
—
150
All timing values are in nanoseconds.
T3
T5
T6
T7
T4
T1
T2
STB*
IBF
INTR
RD*
DATA