Appendix C

Register-Level Programming

PC-DIO-24/PnP User Manual

C-18

© National Instruments Corporation

During a mode 2 data transfer, the status of the handshaking lines and
interrupt signals can be obtained by reading port C. The port C status-
word bit definitions for a mode 2 transfer are shown as follows.

Port C status-word bit definitions for bidirectional data path (port A
only):

Bit

Name

Description

7

OBFA*

Output Buffer for Port A—A low setting indicates that
the CPU has written data to port A.

6

INTE1

Interrupt Enable Bit for Port A Output Interrupts—
Setting this bit enables output interrupts from port A
of the 82C55A. This bit is controlled by
setting/resetting PC6.

5

IBFA

Input Buffer for Port A—A high setting indicates that
data has been loaded into the input latch of port A.

4

INTE2

Interrupt Enable Bit for Port A Input Interrupts—
Setting this bit enables input interrupts from port A of
the 82C55A. This bit is controlled by setting/resetting
PC4.

3

INTRA

Interrupt Request Status for Port A—If INTE1 and
IBFA are high, then this bit is high, indicating that an
interrupt request is pending for port A input transfers.
If INTE2 and OBFA* are high, then this bit is high,
indicating that an interrupt request is pending for
port A output transfers.

2–0

I/O

Input/Output—These bits can be used for general-
purpose I/O lines if group B is configured for mode 0.
If group B is configured for mode 1, refer to the bit
explanations shown in the preceding mode 1 sections.

D7

D6

D5

D4

D3

D2

D1

D0

OBFA*

INTE1

IBFA

INTE2

INTRA

I/O

I/O

I/O