N-Ring – Configuration

The Configuration tab under the N-Ring category will display the N-Ring basic configuration

settings. By default N-Ring is in AutoMember mode and the N-Ring agingtime is 20 seconds.

Following the Modify button on the previous page, the administrator will see a list of configurable

fields for the N-Ring configuration, as below.


The N-Ring Agingtime has a default of 20 seconds and is separate from the Bridging Aging Time.

N-Ring Aging time is used for the whole switch if the switch is an N-Ring Manager or becomes an active
N-Ring Member, and in either case N-Ring status includes for example:

“Switch is currently using N-Ring Aging Time = 20 Seconds”

Once these fields are filled in to meet the needs of the administrator’s network the changes may be

saved by clicking the Update button at the bottom of the page.

NOTES:

1.

N-Ring Manager cannot have RSTP or Trunking enabled.

2.

RSTP & N-Ring are different modes and cannot have redundant links along those lines.
See the examples in the RSTP configuration section.