CHAPTER 17 SERIAL INTERFACE CHANNEL 0 (

µ

PD78054Y Subseries)

(c) Interrupt timing specification register (SINT)

SINT is set by the 1-bit or 8-bit memory manipulation instruction.

RESET input sets SINT to 00H.

R/W

WAT1

WAT0

Interrupt control by wait (See

Note 2

)

0

0

Interrupt service request is generated on rise of 8th SCK0 clock cycle (clock output is high
impedance).

0

1

Setting prohibited

1

0

Used in I

2

C bus mode (8-clock wait)

Generates an interrupt service request on rise of 8th SCL clock cycle. (In case of master device,
SCL pin is driven low after output of 8 clock cycles, to enter the wait state. In case of slave device,
SCL pin is driven low after input of 8 clock cycles, to require the wait state.)

1

1

Used in I

2

C bus mode (9-clock wait)

Generates an interrupt service request on rise of 9th SCL clock cycle. (In case of master device,
SCL pin is driven low after output of 9 clock cycles, to enter the wait state. In case of slave device,
SCL pin is driven low after input of 9 clock cycles, to require the wait state.)

R/W

WREL

Wait release control

0

Indicates that the wait state has been released.

1

Releases the wait state. Automatically cleared to 0 after releasing the wait state. This bit is used to release
the wait state set by means of WAT0 and WAT1.

R/W

CLC

Clock level control

0

Used in I

2

C bus mode. In cases other than serial transfer, SCL pin output is driven low.

1

Used in I

2

C bus mode. In cases other than serial transfer, SCL pin output is set to high impedance. (Clock

line is held high.) Used by master device to generate the start condition and stop condition signals.

R/W

SVAM

SVA bits used as slave address

0

Bits 0 to 7

1

Bits 1 to 7

R/W

SIC

INTCSAI0 interrupt source selection

Note 3

0

CSIIF0 is set to 1 after end of serial interface channel 0 transfer.

1

CSIIF0 is set to 1 after end of serial interface channel 0 transfer or when stop condition is detected.

R

CLD

SCL pin level (See

Note 4

)

0

Low level

1

High level

Notes 1. Bit 6 (CLD) is read-only.

2. When the I

2

C bus mode is used, be sure to set 1 and 0, or 1 and 1 in WAT0 and WAT1, respectively.

3. When using the wake-up function in I

2

C mode, be sure to set SIC to 1.

4. When CSIE0 = 0, CLD is 0.

Remark

SVA

: Slave address register

CSIIF0 : Interrupt request flag corresponding to INTCSI0

CSIE0 : Bit 7 of serial operating mode register 0 (CSIM0)

<6>

<5>

<4>

<3>

<2>

1

0

7

Symbol

SINT

0

CLD

SIC

FF63H 00H R/W

Note1

Address After Reset R/W

SVAM CLC WREL WAT1 WAT0

Advertising