4. Install the lamp cover.
5. Tighten the screw to the lamp cover.

6. Connect the plug to the mains socket.
7. Open the door. Make sure that the light comes on.

Technical data

Dimension of the recess

Height

1446 mm

Width

560 mm

Depth

550 mm

Rising Time

20 h

Voltage

230-240 V

Frequency

50 Hz

The technical information are situated in the rating plate
on the internal left side of the appliance and in the ener-
gy label.

Installation

Caution! Read the "Safety Information" carefully
for your safety and correct operation of the

appliance before installing the appliance.

Positioning

Install this appliance at a location where the ambient
temperature corresponds to the climate class indicated
on the rating plate of the appliance:

Climate

class

Ambient temperature

SN

+10°C to + 32°C

N

+16°C to + 32°C

ST

+16°C to + 38°C

T

+16°C to + 43°C

Electrical connection

Before plugging in, ensure that the voltage and fre-
quency shown on the rating plate correspond to your
domestic power supply.
The appliance must be earthed. The power supply ca-
ble plug is provided with a contact for this purpose. If
the domestic power supply socket is not earthed, con-
nect the appliance to a separate earth in compliance

with current regulations, consulting a qualified electri-
cian.
The manufacturer declines all responsibility if the above
safety precautions are not observed.
This appliance complies with the E.E.C. Directives.

Door reversibility

The door of the appliance opens to the right. If you
want to open the door to the left, do these steps before
you install the appliance:

Loosen the upper pin and
remove the spacer.
Remove the upper pin
and the upper door.

Loosen the middle hinge.