Security Settings

150

ƒ Enforce at least one printable special character. When checked, at

least one special character (printable) is required in the
password.

ƒ Number of restricted passwords based on history. This field

represents the password history depth; that is, the number of
prior passwords that cannot be repeated. The range is 1-12; the
default is 5.

User Blocking

The User Blocking options specify the criteria in which users are blocked
from accessing the system after the specified number of unsuccessful
login attempts. The three options are mutually exclusive:

• Disabled. The default option; users are not blocked regardless of the

number of times they fail authentication.

• Timer Lockout. Users are denied access to the system for the

specified amount of time after exceeding the specified number of
unsuccessful login attempts. When selected, the following fields are
enabled:

ƒ Attempts. The number of unsuccessful login attempts after which

the user will be locked out. The valid range is 1 - 10; the default
is 3 attempts.

ƒ Lockout Time. The amount of time for which the user will be

locked out. The valid range is 1 - 1440 minutes; the default is 5
minutes.