Installation, Venting – Regency Panorama P36D User Manual

Page 21

Advertising
background image

FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace

21

VENTING

Direct Vent System (Flex)

Horizontal Terminations Only

These venting systems, in combination with the P36D-1 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by
Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in "Exterior Vent
Termination Locations" section.

FPI Direct Vent Flex System Termination Kit (Part # 946-515) includes all the parts needed to install the P36D-1 with a maximum run of
4 feet.

1) 6-7/8" dia. fl exible liner (4 ft. length)
2) 4" dia. fl exible liner (4 ft. length)
3) spring spacers (4)
4) thimble (2)
5) AstroCap termination cap (1)
6) screws (12)
7) tube of Mill Pac (1)
8) plated screws (8)
9) screws #8 x 1-1/2" Drill Point, Stainless

Steel (4)

If longer runs are needed, the FPI Direct
Vent system (Flex) # 946-516 includes all
the parts needed to install the P36D-1 with
a maximum 10' run.

1) 6-7/8" dia. fl exible liner (10 ft. length)
2) 4" dia. fl exible liner (10 ft. length)
3) spring spacers (7)
4) thimble (2)
5) AstroCap termination cap (1)
6) screws (12)
7) tube of Mill Pac (1)
8) plated screws (8)
9) screws #8 x 1-1/2" Drill Point, Stainless

Steel (4)

Notes

:


1) Liner sections should be continuous without any joints or seams.

2) Only Flex pipe purchased from FPI may be used for Flex installations.

INSTALLATION

Advertising