FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace

61

REGENCY™ SERIES OPTIONS

THE BALMORAL

®

FRONT INSTALLATION

6) For optional fan installation, see "Optional Fan Installation" section.

7) For 2-panel & 3-panel door installation, see "2-Panel Door Installation

& 3-Panel Door Installation" sections.

1) Bend tabs located at the back of the Balmoral Front upwards 90

degrees.

B e n d t a b
upwards 90
degrees.

Backside of Front shown.

2) Secure the bottom frame of the Front by loosening the inner screw

on the hinge brackets on both the left and right side of the fi rebox.
Slide frame in place and secure.

Left Side Shown

Hinge bracket on

bottom of fi rebox

4) Remove existing control switch box from under fi rebox by disconnecting

wires connected to the valve at TH-TH/TP terminals and discard.

Wires connected to Valve.

Control Box

3) Slide tabs into louver brackets located on the inside top of the

fi rebox.

Tabs

Bracket inside
top of fi rebox.

Balmoral Front

frame

5) Connect the ON/OFF switch wires coming from the left side of the

Front to the valve, with black hooked up to the TH/TP terminal and
red hooked up to the TH terminal.

NOTE: If fan option is not used please see step (5) of optional fan
installation for placement of fan control box.

Valve

ON/OFF Switch

Wires

Fan Control Box